Fluke 3000 FC Series Wireless True-RMS Digital Multimeter

$1,141.59

  • Full featured multimeter that also reads results wirelessly from remote Fluke Connect® wireless modules
  • Measures AC and DC voltage to 1000 V, AC and DC current, and temperature
  • Shows up to four readings simultaneously on a bright white backlit display
  • Sends measurement data to your smartphone
  • Safety rated CAT III 1000 V, Cat IV 600 V; IP54

    Contact Information








    WhatsApp us

    Category: Brand:

    Specifications: Fluke 3000 FC Series Wireless Multimeter

    AC Voltage
    Range¹ / resolution 600.0 mV / 0.1 mV
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy2 3 4 45 Hz to 500 Hz 1.0% + 3
    500 Hz to 1 kHz 2.0% + 3
    1. AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    mV Range / resolution 600.0 mV / 0.1 mV
    Accuracy 0.09% + 2
    V Range / resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 0.09% + 2
    0.15% + 2
    ))) Range / resolution 600 Ω / 1 Ω
    Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Ω Range / resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    60.00 kΩ / 0.1 kΩ
    600.0 kΩ / 0.001 MΩ
    50.00 MΩ / 0.01 MΩ
    Accuracy 0.5% + 2
    0.5% + 1
    1.5% + 3
    Diode test Range / resolution 2.000 V / 0.001 V
    Accuracy 1% + 2
    µF Range / resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF1 / 1 μF
    Accuracy 1.2% + 2
    10% typical
    1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
    AC and DC Current
    mA AC
    (45 Hz to 1 kHz)
    Range1 / resolution 60.00 mA / 0.01 mA
    400.0 mA/ 0.1 mA
    Accuracy 1.5% + 3
    mA DC2 Range1 / resolution 60.00 mA / 0.01 mA
    400.0 mA3 / 0.1 mA
    Accuracy 0.5% + 3
    1. All AC current ranges are specified from 5% of range to 100% of range.
    2. Input burden voltage (typical): 400 mA input 2 mV/mA.
    3. 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    Range / resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 kHz
    99.99 kHz / 0.01 kHz
    Accuracy1 0.1% + 1
    1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Overload protection 1100 V RMS
    Input impedance (nominal) > 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 120 dB at DC, 50 Hz or 60 Hz
    Normal mode rejection > 60 dB at 50 Hz or 60 Hz
    Overload protection 1100 V RMS
    Input impedance (nominal) > 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 60 dB, DC to 60 Hz
    Normal mode rejection > 60 dB at 50 Hz or 60 Hz
    Overload protection 1100 V RMS
    Input impedance (nominal) > 10 MΩ < 100 pF
    Common mode rejection ratio
    (1 kΩ unbalance)
    > 120 dB at DC, 50 Hz or 60 Hz
    Normal mode rejection > 60 dB at 50 Hz or 60 Hz
    Open Circuit Test Voltage
    Overload protection 1100 V RMS
    Input impedance (nominal) < 2.7 V DC
    Full scale voltage to 6 MΩ
    Full scale voltage 50 MΩ
    < 0.7 V DC
    < 0.9 V DC
    Typical short circuit current < 350 mA
    Overload protection 1100 V RMS
    Input impedance (nominal) < 2.7 V DC
    Full scale voltage to 6 MΩ
    Full scale voltage 50 MΩ
    2.000 V DC
    Typical short circuit current < 1.1 mA
    mA Function
    Overload protection Fused, 44/100 A, 1000 V FAST Fuse
    Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording Accuracy
    DC functions ± 12 counts for changes > 350 mS in duration.
    AC functions ± 40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate 4/sec
    Volts, amps, ohms 6000 counts
    Frequency 10,000 counts
    Capacitance 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 250 hours minimum
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20m
    Obstructed, sheetrock wall Up to 6.5m
    Obstructed, concrete wall, or steel electrical enclosure Up to 3.5m
    Temperature Operating -10°C to 50°C
    Storage -40°C to 60°C
    Temperature coefficient 0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
    Relative humidity 0% to 90% (0°C to 35°C)
    0% to 75% (35°C to 40°C)
    0% to 45% (40°C to 50°C)
    Altitude Operating 2,000 m
    Storage 12,000 m
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326–1:2006, EN 61326–2–2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008
    FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
    Safety compliance ANSI / ISA 61010–1 / (82.02.01): 3rd edition
    CAN / CSA-C22.2 No 61010-1-12: 3rd edition
    UL 61010–1: 3rd edition
    IEC / EN 61010–1:2010
    Certifications CSA, FCC, CE
    Ingress Protection (IP) rating IP54
    Pollution Degree 2
    Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
    Weight 340 g (12 oz)
    Warranty Three years
    Not compatible with Fluke CNX test tools