Fluke 393FC CAT III 1500V True-RMS Clamp Meter with iFlex, Solar Irradiance Meter, MC4 Leads, and Proving Unit

$1,169.13

  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes
  • Sturdy IP54 rated for outdoor use and solar installation
  • Work efficiently with dc power measurement, audio polarity and visual continuity

    Contact Information








    WhatsApp us

    Category: Brand:

    Specifications: Fluke 393 FC Solar Clamp Meter CAT III 1500 V

    Specifications:
    General
    Maximum voltage between any Terminal and Earth Ground
    AC 1000 V
    DC 1500 V
    Batteries 2 AA IEC LR6 alkaline
    Display Dual display with backlight
    Automatic Power Off 20 minutes
    Electrical
    Accuracy
    Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
    Temperature Coefficients Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
    AC Current: Jaw
    Range 999.9 A
    Resolution 0.1 A
    Accuracy 2 % + 5 digits (10 Hz to 100 Hz)
    2.5 % + 5 digits (100 Hz to 500 Hz)
    Crest Factor (50/60 Hz) 2.5 @600.0 A
    3.0 @500.0 A
    1.42 @999.9 A
    Add 2 % for C.F. >2
    AC Current: Flexible Current Probe
    Range 999.9 A
    2500 A
    Resolution 0.1 A (≤999.9 A)
    1 A (≤2500 A)
    Accuracy 3 % RD + 5 digits (10 Hz to 500 Hz)
    Crest Factor (50/60Hz) 2.5 @1400 A
    3.0 @1100 A
    1.42@2500 A
    Add 2 % for C.F. >2
    Position Sensitivity
    NEC symbol
    Distance from Optimum i2500-10 Flex i2500-18 Flex Error
    A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 %
    B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 %
    C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 %
    Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
    DC Current
    Range 999.9 A
    Resolution 0.1 A
    Accuracy 2 % RD + 5 digits[1]
    [1] When using the ZERO (B) function to compensate for offsets.
    AC Voltage
    Range 600.0 V
    1000 V
    Resolution 0.1 V (≤600.0 V)
    1 V (≤1000 V)
    Accuracy 1 % RD + 5 digits (20 Hz to 500 Hz)
    DC Voltage
    Range 600.0 V
    1500 V
    Resolution 0.1 V (≤600.0 V)
    1 V (≤1500 V)
    Accuracy 1 % RD + 5 digits
    mV dc
    Range 500.0 mV
    Resolution 0.1 mV
    Accuracy 1 % RD + 5 digits
    Amps Frequency: Jaw
    Range 5.0 Hz to 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5 % RD + 5 digits
    Trigger Level 5 Hz to 10 Hz, ≥10 A
    10 Hz to 100 Hz, ≥5 A
    100 Hz to 500 Hz, ≥10 A
    Amps Frequency: Flexible Current Probe
    Range 5.0 Hz to 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5 % RD + 5 digits
    Trigger Level 5 Hz to 20 Hz, ≥25 A
    20 Hz to 100 Hz, ≥20 A
    100 Hz to 500 Hz, ≥25 A
    Voltage Frequency
    Range 5.0 Hz to 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5 % RD + 5 digits
    Trigger Level 5 Hz to 20 Hz, ≥5 V
    20 Hz to 100 Hz, ≥5 V
    100 Hz to 500 Hz, ≥10 V
    DC Power
    Range 600.0 kVA (600.0 V dc range)
    1500 kVA (1500 V dc range)
    Resolution 0.1 kVA
    1 kVA
    Accuracy 2 % RD + 2.0 kVA
    2 % RD + 20 kVA
    Resistance
    Range 600.0 Ω
    6000 Ω
    60.00 kΩ
    Resolution 0.1 Ω (≤600.0 Ω)
    1 Ω (≤6000 Ω)
    0.01 kΩ (≤60.00 kΩ)
    Accuracy 1 % RD + 5 digits
    Capacitance
    Range 100.0 μF
    1000 μF
    Resolution 0.1 μF (≤100.0 μF)
    1 μF (≤1000 μF)
    Accuracy 1 % RD + 5 digits
    Inrush Trigger Level 5 A
    Mechanical
    Size (L x W x H) 281 mm x 84 mm x 49 mm
    Weight (with batteries) 520 g
    Jaw Opening 34 mm
    Flexible Current Probe Diameter 7.5 mm
    Flexible Current Probe Cable Length
    (head to electronics connector) 1.8 m
    Environmental
    Operating Temperature -10 °C to 50 °C
    Storage Temperature -40 °C to 60 °C
    Operating Humidity Non condensing (<10°C)
    ≤90 % RH (at 10 °C to 30 °C)
    ≤75 % RH (at 30 °C to 40 °C)
    ≤45 % RH (at 40 °C to 50 °C)
    Operating Altitude 2000 m
    Storage Altitude 12 000 m
    Ingress Protection (IP) Rating IEC 60529: IP54 non-operating
    Electromagnetic Compatibility (EMC)
    International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
    Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
    Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
    Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
    Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
    Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
    USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Safety
    General IEC 61010-1, Pollution Degree 2
    Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
    IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
    Wireless Radio
    Radio frequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE
    Wireless Radio Frequency Range 2400 MHz to 2483.5 MHz
    Output Power <100 mW
    SIMPLIFIED EU DECLARATION OF CONFORMITY
    Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.