Overview
The Hantek HRDO2000 Series is designed for engineers and technical users who need higher measurement precision, broader test visibility, and more integrated tools in one bench instrument. According to Hantek’s official product materials, the series provides 12-bit vertical resolution, up to 500MHz bandwidth, up to 2.5GSa/s sampling, waveform capture rates above 1.1 million waveforms per second, and up to 2Gpts memory depth. This combination makes the HRDO2000 Series suitable for capturing both subtle signal details and short-duration anomalies that may be missed by lower-resolution or slower-update instruments.
What makes the HRDO2000 Series especially attractive for procurement teams and lab managers is its high level of functional integration. Hantek positions the platform as an 8-in-1 instrument, combining a 4-channel oscilloscope, 16-channel logic analyzer, spectrum analyzer, arbitrary waveform generator, digital voltmeter, frequency meter and accumulator, protocol analyzer, and protocol generator in one system on supported models. This reduces the need for multiple standalone instruments, simplifies the test bench, and can improve workflow efficiency in R&D, maintenance, production support, and education environments.
The series also features a 10.1-inch multi-touch capacitive display with 256-level waveform grayscale and color temperature display, helping users interpret waveform persistence and signal behavior more clearly. Hantek further highlights rich serial triggering and decoding support plus analysis functions such as histogram, Bode plotting, power analysis, search, navigation, waveform recording, DVM, and frequency counting. These features make the HRDO2000 Series well suited to engineers working with mixed-signal systems, switching power supplies, industrial control electronics, and embedded communication interfaces.
Key Features
The HRDO2000 Series stands out because it combines high-resolution acquisition with broad application flexibility. Official specifications show that the series supports 4 analog channels, while the E-series models add 16 digital channels and a 1-channel 50MHz signal source. For teams developing or troubleshooting digital and analog subsystems together, this can be a major advantage, allowing time-correlated mixed-signal analysis from a single interface.
Another strong advantage is measurement depth and capture performance. The HRDO2000 Series supports 2Gpts memory depth at maximum and more than 2 million frames of hardware recording and playback on a single channel. Hantek also lists 51 automatic waveform measurements on the product page, while the current user manual screenshot mentions 52 automatic measurements. Because the official sources are inconsistent on this single point, it is safer for the product page to use “up to 51+ automatic measurements” or to stay with the product-page wording of 51 until your team confirms the latest firmware behavior.
The platform also supports common serial bus work. Official materials list triggering and decoding for UART, I2C, SPI, LIN, and CAN, which are essential for embedded system validation, automotive electronics troubleshooting, and industrial communication development. Mathematical functions include A+B, A-B, A×B, A/B, FFT, logic operations, integration, differentiation, square root, logarithmic and exponential functions, and filter options, giving engineers more built-in analysis tools without extra software.
Applications
The Hantek HRDO2000 Series is well suited for a range of professional use cases:
-
Embedded system debugging for MCU, FPGA, and mixed-signal boards using analog plus serial-bus analysis.
-
Power electronics and power supply analysis with tools such as waveform recording, power analysis, and Bode plotting support described by Hantek.
-
Industrial control and maintenance where technicians need a single platform for waveform inspection, logic checking, and protocol troubleshooting.
-
Electronics education and training labs that benefit from an integrated oscilloscope and signal generation environment. This is an inference based on the instrument’s multi-function integration and not a stated official market segment.
-
General R&D bench testing where higher vertical resolution, deeper memory, and multi-channel visibility improve debugging speed.
Technical Specifications
| Specification | Verified Details |
|---|---|
| Product Family | Hantek HRDO2000 Series |
| Analog Channels | 4 channels |
| Bandwidth Options | 100MHz / 200MHz / 350MHz / 500MHz depending on model |
| Vertical Resolution | 12-bit |
| Real-Time Sampling Rate | Up to 2.5GSa/s |
| Memory Depth | Up to 2Gpts |
| Waveform Capture Rate | Above 1.1 million wfms/s |
| Time Base Accuracy | ±1 ppm |
| Vertical Sensitivity | 1MΩ: 500μV/div to 10V/div; 50Ω: 500μV/div to 1V/div |
| Trigger Types | Edge, Pulse, Video, Slope, Window, Logic, Delay, Setup/Hold, Nth Edge, UART, LIN, CAN, SPI, I2C and more |
| Bus Decode | UART, I2C, SPI, LIN, CAN |
| Math Functions | Arithmetic, FFT, logic, filters, integration, differentiation, expression |
| Analysis Functions | Frequency meter, DVM, power analysis, histogram, search, navigation, record, Bode plot/set |
| Hardware Recording | More than 2 million frames (single channel) |
| Digital Channels | 16 channels on E-series models |
| Arbitrary Waveform Generator | 1 channel, up to 50MHz on E-series models |
| Interfaces | USB Host, USB Device, LAN; optional HDMI, serial port |
| Display | 10.1-inch multi-touch capacitive screen |
| Included Probe Guidance | Model-dependent passive probes; e.g. HT-100B / HT-200B / HT300B / HT500B by bandwidth tier |
| Model Variants | HRDO2104E / 2204E / 2354E / 2504E and HRDO2104C / 2204C / 2354C / 2504C |
All technical values above are taken from Hantek’s official product page and manual.
Package Contents
Standard accessories shown on the official product page include passive probe(s), power cord, packing list, calibration certificate, warranty card, certificate of conformity, and data cable. Probe model varies by bandwidth version. For ecommerce accuracy, it is best to list accessories as “standard accessories may vary by selected model and region” unless your warehouse BOM is fixed.
Call to Action
Upgrade your bench with the Hantek HRDO2000 Series and give your engineering team a higher-resolution, multi-function test platform built for modern analog and mixed-signal workflows. Choose the bandwidth and configuration that fits your application, then contact us for model selection, quotation, and lead-time support.
【FAQ】
Q1: What is the Hantek HRDO2000 Series?
A: The Hantek HRDO2000 Series is a family of 4-channel digital oscilloscopes with 12-bit resolution, up to 500MHz bandwidth, and up to 2.5GSa/s real-time sampling. Selected E-series models also include a 16-channel logic analyzer and built-in waveform generator.
Q2: Which HRDO2000 models include the logic analyzer and waveform generator?
A: According to the official model list, the E-series models include 16 digital channels and a 1-channel signal source, while the C-series models do not.
Q3: What bandwidth options are available in the HRDO2000 Series?
A: Official Hantek sources list 100MHz, 200MHz, 350MHz, and 500MHz variants within the series.
Q4: Does the HRDO2000 support serial protocol triggering and decoding?
A: Yes. Hantek lists support for UART, I2C, SPI, LIN, and CAN triggering and decoding.
Q5: Is a GTIN available for the Hantek HRDO2000 Series?
A: I did not find a verified GTIN in the official Hantek product page or manual reviewed here. It is better to leave GTIN blank in schema unless your supplier or packaging confirms it.






Reviews
There are no reviews yet.