Fluke I430-FLX-TFII-48 Flexible AC Current Clamp 48 Inch for 430-II Series, 6000A

$687.98

The i430 Flex is an AC current probe utilizing the Rogowski principle. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas, without batteries or an external power source.

Also available as a pack of 4 pieces of the i430 current clamp, to be used for high current measurements. The Flex clamp fits around bus bars and large or hard-to-reach conductors. This 4-pack is perfect for use with 3-phase tools such as the Fluke 430 series.

    Contact Information








    WhatsApp us

    Category: Tag: Brand:

    Specifications: Fluke i430 Flex Current Clamp

    General Specifications
    Probe and cable material TPE rubber, reinforced insulation
    UL94 V-0, Colour: RED Munsell 7.5
    R 1/14
    Couplings material Polypropylene, UL94 V-0
    Probe cable length 610 mm
    Probe cable diameter 12.4 mm
    Probe cable bend radius 40 mm
    Output cable length 2.5 meters RG58
    Output connector Safety BNC Connector
    Operating range -20 to +90°C
    Storage temperature -40 to +105°C
    Operating humidity 15% to 85% (non condensing)
    Degree of protection (Probe) IP41
    Specifications
    Current range 3000 A AC rms
    Voltage output (@ 1000 A rms, 50 Hz) 85 mV
    Accuracy ±1% of reading
    (@ 25°C, 50 Hz)
    Linearity (10% to 100% of range) ±0.2% of reading
    Noise (10 Hz – 7 kHz) 1.0 mV AC rms
    Output impedance 82 Ω min
    Load impedance 50 kΩ
    Internal Resistance per 100 mm probe length 10.5Ω ±5%
    Bandwidth (-3dB) 10 Hz to 7 kHz
    Phase error (45 – 65 Hz) ±1°
    Position sensitivity ±2% of reading max.
    Temperature coefficient ±0.08% max of reading per °C
    Working voltage (see Safety standards section) 1000 V AC rms or DC (head)
    30 V max. (output)
    Safety Specifications
    Safety standards BS EN 61010-1 2001
    BS EN 61010-2-032 2002
    BS EN 61010-031 2002, 1000 VRMS, Category III, Pollution Degree 2
    Use of the probe on uninsulated conductors is limited to 1000 V AC rms or DC and frequencies below 1 kHz.
    Please note that this probe is designed to work with Fluke 435, if used with other products
    Safety rating for the output to earth is limited to 600 V AC rms or DC.